CBI Time Switch + Back Up
Maximum Load Resistive (Geysers, under floor heating, lights) – 21 A
Contact Endurance – 20 000 (minimum) Operations
Degree of Ingress Protection (When installed in distribution panel) – IP40 (not waterproofed)
Operating Temperature – 20 °C to +55 °C
Single Segment Period – 15 min.
Clock Accuracy – + 3 min. per month
Maximum Period for all Segments – 96 x 15 min. Segments
Time Retention (Power Outage) – 24 h
The programmable time switch can be used to automatically control pool pumps, lights, geysers, etc.I. During a power failure, the symbol is displayed and the time switch enters standby. After a few hours, the display will turn off completely.
2. The time switch has a backup power feature which requires I hour to charge.
3. In the event of a power failure, a fully charged time switch will keep time for up to 24 hours.The programmed schedule is always retained.